freebsd-ports/sysutils/apcupsd/Makefile
Ion-Mihai Tetcu 8f93fe176d Update to 3.14.4.
Notable changes are:
- it now builds using gmake
- NLS and POWERFLUTE are removed
- POLLTIME directive to control UPS polling interval. This directive
    specifies the number of seconds to delay between polling the UPS for
    status. Previously, NETTIME allowed this to be adjusted for network
    connections only (snmp, pcnet, nis-net). POLLTIME configures the delay
    for all connection types. NETTIME is accepted as a synonym for
    compatibility with old config files.
- you can now use the graphical client via GAPCMON OPTION
- it won't build on anything pre 6.3R

Tested by:	Stefan Lambrev <stefan.lambrev@moneybookers.com>
2008-07-10 20:03:47 +00:00

174 lines
4.9 KiB
Makefile

# New ports collection makefile for: apcupsd
# Date created: 1.12.2001
# Whom: Lars Köller <Lars.Koeller@Uni-Bielefeld.DE>
#
# $FreeBSD$
#
PORTNAME= apcupsd
PORTVERSION= 3.14.4
CATEGORIES= sysutils
MASTER_SITES= ${MASTER_SITE_SOURCEFORGE:S/$/:src_sf/g} \
http://T32.TecNik93.com/FreeBSD/ports/${PORTNAME}/sources/:src_bk \
http://apcupsd.sourceforge.net/manual/:doc_sf \
http://T32.TecNik93.com/FreeBSD/ports/${PORTNAME}/sources/:doc_bk
MASTER_SITE_SUBDIR= ${PORTNAME}/:src_sf
DISTFILES= ${DISTNAME}${EXTRACT_SUFX}:src_sf,src_bk \
${PORTNAME}.pdf:doc_sf,doc_bk
EXTRACT_ONLY= ${DISTNAME}${EXTRACT_SUFX}
#IGNOREFILES= ${PORTNAME}.pdf
MAINTAINER= itetcu@FreeBSD.org
COMMENT= Set of programs for controlling APC UPS
USE_RC_SUBR= apcupsd
SUB_FILES= pkg-message
GNU_CONFIGURE= yes
USE_GMAKE= yes
CONFIGURE_ARGS= --sbindir=${PREFIX}/sbin \
--with-nologin=/var/run \
--disable-install-distdir \
--sysconfdir=${ETCDIR} \
--with-serial-dev=/dev/usv
CONFIGURE_ENV= CPPFLAGS="-I${LOCALBASE}/include -L${LOCALBASE}/lib" \
CFLAGS="-I${LOCALBASE}/include -L${LOCALBASE}/lib" \
LDFLAGS="-L${LOCALBASE}/lib"
MAN8= apcupsd.8
OPTIONS= APCSMART_DRV "Compile APC SmartUPS serial driver" on \
APCDUMB_DRV "Compile dumb UPS driver" on \
CLIENT_ONLY "Only NIS client (no network server or drivers)" off \
CGI "Compile with CGI programms to show status" off \
PCNET_DRV "Compile PowerChute Network Shutdown driver" on \
USB "Compile with USB Support driver" on \
SNMP_DRV "Compile with SNMP driver" on \
TCP_WRAPPERS "Compile with TCP_WRAPPERS support" on\
TEST_DRV "Compile TEST driver" off \
GAPCMON "Build GTK GUI front-end" off
# POWERFLUTE "Compile powerflute program" off
PORTDOCS= ${PORTNAME}.pdf
.include <bsd.port.options.mk>
.ifdef(WITH_APCSMART_DRV)
CONFIGURE_ARGS+= --enable-apcsmart
.else
CONFIGURE_ARGS+= --disable-apcsmart
.endif
.ifdef(WITH_APCDUMB_DRV)
CONFIGURE_ARGS+= --enable-dumb
.else
CONFIGURE_ARGS+= --disable-dumb
.endif
.ifdef(WITH_CLIENT_ONLY)
CONFIGURE_ARGS+= --enable-net \
--disable-apcsmart --disable-dumb --disable-usb \
--disable-snmp --disable-test --disable-pcnet
.endif
.ifdef(WITH_CGI)
CONFIGURE_ARGS+= --enable-cgi --with-cgi-bin=${ETCDIR}/cgi
LIB_DEPENDS+= gd.4:${PORTSDIR}/graphics/gd
PLIST_SUB+= CGI=""
.else
PLIST_SUB+= CGI="@comment "
.endif
.ifdef(WITH_GAPCMON)
CONFIGURE_ARGS+= --enable-gapcmon
USE_GNOME+= gconf2
PLIST_SUB+= GAPCMON=""
.else
PLIST_SUB+= GAPCMON="@comment "
.endif
.ifdef(WITH_PCNET_DRV)
CONFIGURE_ARGS+= --enable-pcnet
.else
CONFIGURE_ARGS+= --disable-pcnet
.endif
# disabled upstream
.ifdef(WITH_POWERFLUTE)
CONFIGURE_ARGS+= --enable-powerflute
CONFIGURE_ENV+= LIBS+="-lcurses -lmenu"
PLIST_SUB+= POWERFL=""
.else
PLIST_SUB+= POWERFL="@comment "
.endif
.ifdef(WITH_USB)
CONFIGURE_ARGS+= --enable-usb
.endif
.ifdef(WITH_SNMP_DRV)
LIB_DEPENDS+= netsnmp.16:${PORTSDIR}/net-mgmt/net-snmp
CONFIGURE_ARGS+= --enable-snmp
.else
CONFIGURE_ARGS+= --disable-snmp
.endif
.ifdef(WITH_TCP_WRAPPERS)
CONFIGURE_ARGS+= --with-libwrap=yes
.endif
.ifdef(WITH_TEST_DRV)
CONFIGURE_ARGS+= --enable-test
.endif
#CONFIGURE_ARGS+= --with-libwrap=yes
#CONFIGURE_ENV+= LIBS="-lcurses -lmenu"
#PLIST_SUB+= POWERFL=""
.include <bsd.port.pre.mk>
pre-configure:
.if defined(WITH_CLIENT_ONLY) && ( defined(WITH_APCSMART_DRV) || \
defined(WITH_APCDUMB_DRV) || defined(WITH_PCNET_DRV) || \
defined(WITH_POWERFLUTE) || defined(WITH_USB) || \
definedWITH_SNMP_DRV) || defined(WITH_TEST_DRV) )
@${ECHO_CMD} "It doesn't make sense to build drivers if all you want is"
@${ECHO_CMD} "the client; please do make config and select either"
@${ECHO_CMD} "CLIENT_ONLY or the *_DRV you need"
@${FALSE}
.endif
post-configure:
@${REINPLACE_CMD} -e "s|%PREFIX%|${PREFIX}|g" ${WRKSRC}/doc/apcupsd.man
post-install:
# If the files presaved are identical with the new one, include then in
# the package list. So the port could be removed without problems
for na in apccontrol commfailure mainsback mastertimeout \
changeme commok masterconnect onbattery; do \
if [ -f ${ETCDIR}/$$na.orig ]; then \
if cmp -s ${ETCDIR}/$$na ${ETCDIR}/$$na.orig; then \
${ECHO_CMD} "%%ETCDIR%%/$$na.orig" >> ${TMPPLIST}; \
fi \
fi; \
done
@${ECHO_CMD} "@unexec if [ -d %D/${ETCDIR_REL} ]; then ${ECHO_CMD} \"If you are permanently removing this port, you should do a ``rm -rf ${ETCDIR}`` to remove config files left.\" | ${FMT} ; fi" >> ${TMPPLIST}
# Install sample startup script
# If there is already a config file it is installed as ...new
for na in apcupsd.conf apcupsd.css hosts.conf multimon.conf; do \
if [ -f ${ETCDIR}/$$na ]; then \
if [ -f ${ETCDIR}/$$na.new ]; then \
${MV} ${ETCDIR}/$$na.new ${ETCDIR}/$$na.sample; \
else \
${CP} ${ETCDIR}/$$na ${ETCDIR}/$$na.sample; \
fi; \
fi; \
done
.if !defined(NOPORTDOCS)
@${MKDIR} ${DOCSDIR}
${INSTALL_DATA} ${DISTDIR}/${PORTNAME}.pdf ${DOCSDIR}
.endif
@${CAT} ${PKGMESSAGE}
.include <bsd.port.post.mk>