Blackfin arch: Fix bug set correct baud for spi mmc and enable SPI after DMA.

Changes:

1. The baud for spi mmc defined in board file is not used by the old
spi driver. A slower value from spi framework is used instead. In latest
bug fixing, the correct baud is use which is too high for spi MMC card.

2. SPI is enabled only after DMA is started.

3. MMC detection IRQ is set to 55.

Signed-off-by: Sonic Zhang <sonic.zhang@analog.com>
Signed-off-by: Bryan Wu <bryan.wu@analog.com>
This commit is contained in:
Sonic Zhang 2007-10-30 11:48:42 +08:00 committed by Bryan Wu
parent 0355893e77
commit 111cf97d2c
2 changed files with 4 additions and 4 deletions

View file

@ -218,7 +218,7 @@ static struct spi_board_info bfin_spi_board_info[] __initdata = {
#if defined(CONFIG_SPI_MMC) || defined(CONFIG_SPI_MMC_MODULE)
{
.modalias = "spi_mmc_dummy",
.max_speed_hz = 25000000, /* max spi clock (SCK) speed in HZ */
.max_speed_hz = 20000000, /* max spi clock (SCK) speed in HZ */
.bus_num = 0,
.chip_select = 0,
.platform_data = NULL,
@ -227,7 +227,7 @@ static struct spi_board_info bfin_spi_board_info[] __initdata = {
},
{
.modalias = "spi_mmc",
.max_speed_hz = 25000000, /* max spi clock (SCK) speed in HZ */
.max_speed_hz = 20000000, /* max spi clock (SCK) speed in HZ */
.bus_num = 0,
.chip_select = CONFIG_SPI_MMC_CS_CHAN,
.platform_data = NULL,

View file

@ -450,7 +450,7 @@ static struct spi_board_info bfin_spi_board_info[] __initdata = {
#if defined(CONFIG_SPI_MMC) || defined(CONFIG_SPI_MMC_MODULE)
{
.modalias = "spi_mmc_dummy",
.max_speed_hz = 25000000, /* max spi clock (SCK) speed in HZ */
.max_speed_hz = 20000000, /* max spi clock (SCK) speed in HZ */
.bus_num = 0,
.chip_select = 0,
.platform_data = NULL,
@ -459,7 +459,7 @@ static struct spi_board_info bfin_spi_board_info[] __initdata = {
},
{
.modalias = "spi_mmc",
.max_speed_hz = 25000000, /* max spi clock (SCK) speed in HZ */
.max_speed_hz = 20000000, /* max spi clock (SCK) speed in HZ */
.bus_num = 0,
.chip_select = CONFIG_SPI_MMC_CS_CHAN,
.platform_data = NULL,