clocksource: exynos_mct: Don't reset the counter during boot and resume
Unfortunately on some exynos systems, resetting the mct counter also resets the architected timer counter. This can cause problems if the architected timer driver has already been initialized because the kernel will think that the counter has wrapped around, causing a big jump in printk timestamps and delaying any scheduled clock events until the counter reaches the value it had before it was reset. The kernel code makes no assumptions about the initial value of the mct counter so there is no reason from a software perspective to clear the counter before starting it. This also fixes the problems described in the previous paragraph. Cc: Olof Johansson <olof@lixom.net> Cc: Tomasz Figa <tomasz.figa@gmail.com> Signed-off-by: Chirantan Ekbote <chirantan@chromium.org> Reviewed-by: Doug Anderson <dianders@chromium.org> Tested-by: Doug Anderson <dianders@chromium.org> Signed-off-by: Kukjin Kim <kgene.kim@samsung.com>
This commit is contained in:
parent
cf286b405c
commit
1d80415db6
1 changed files with 3 additions and 6 deletions
|
@ -153,13 +153,10 @@ static void exynos4_mct_write(unsigned int value, unsigned long offset)
|
|||
}
|
||||
|
||||
/* Clocksource handling */
|
||||
static void exynos4_mct_frc_start(u32 hi, u32 lo)
|
||||
static void exynos4_mct_frc_start(void)
|
||||
{
|
||||
u32 reg;
|
||||
|
||||
exynos4_mct_write(lo, EXYNOS4_MCT_G_CNT_L);
|
||||
exynos4_mct_write(hi, EXYNOS4_MCT_G_CNT_U);
|
||||
|
||||
reg = __raw_readl(reg_base + EXYNOS4_MCT_G_TCON);
|
||||
reg |= MCT_G_TCON_START;
|
||||
exynos4_mct_write(reg, EXYNOS4_MCT_G_TCON);
|
||||
|
@ -181,7 +178,7 @@ static cycle_t exynos4_frc_read(struct clocksource *cs)
|
|||
|
||||
static void exynos4_frc_resume(struct clocksource *cs)
|
||||
{
|
||||
exynos4_mct_frc_start(0, 0);
|
||||
exynos4_mct_frc_start();
|
||||
}
|
||||
|
||||
struct clocksource mct_frc = {
|
||||
|
@ -200,7 +197,7 @@ static u64 notrace exynos4_read_sched_clock(void)
|
|||
|
||||
static void __init exynos4_clocksource_init(void)
|
||||
{
|
||||
exynos4_mct_frc_start(0, 0);
|
||||
exynos4_mct_frc_start();
|
||||
|
||||
if (clocksource_register_hz(&mct_frc, clk_rate))
|
||||
panic("%s: can't register clocksource\n", mct_frc.name);
|
||||
|
|
Loading…
Reference in a new issue