Staging: octeon: Add missing of_node_put after calling of_parse_phandle.

of_node_put needs to be called when the device node which is got
from of_parse_phandle is no longer used.
This patch is found by below coccinelle script:

@@
expression e,e1,e2;
@@
*e = of_parse_phandle(...)
... when != of_node_put(e)
    when != true e == NULL
    when != e2 = e
e = e1

Signed-off-by: Sandhya Bankar <bankarsandhya512@gmail.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Sandhya Bankar 2016-09-18 23:02:33 +05:30 committed by Greg Kroah-Hartman
parent cd9ae9e4db
commit 24586a35d3

View file

@ -168,6 +168,7 @@ int cvm_oct_phy_setup_device(struct net_device *dev)
phydev = of_phy_connect(dev, phy_node, cvm_oct_adjust_link, 0,
PHY_INTERFACE_MODE_GMII);
of_node_put(phy_node);
if (!phydev)
return -ENODEV;