ath10k: fix hwmon temperature input units
To be compliant with the hwmon interface the unit needs to be millidegree Celsius. Fix that. Reported-by: Matthias Kaehlcke <mka@google.com> Signed-off-by: Rajkumar Manoharan <rmanohar@qti.qualcomm.com> Signed-off-by: Kalle Valo <kvalo@qca.qualcomm.com>
This commit is contained in:
parent
f6eaf1e063
commit
6d48161678
1 changed files with 2 additions and 1 deletions
|
@ -160,7 +160,8 @@ static ssize_t ath10k_thermal_show_temp(struct device *dev,
|
|||
temperature = ar->thermal.temperature;
|
||||
spin_unlock_bh(&ar->data_lock);
|
||||
|
||||
ret = snprintf(buf, PAGE_SIZE, "%d", temperature);
|
||||
/* display in millidegree celcius */
|
||||
ret = snprintf(buf, PAGE_SIZE, "%d\n", temperature * 1000);
|
||||
out:
|
||||
mutex_unlock(&ar->conf_mutex);
|
||||
return ret;
|
||||
|
|
Loading…