Bluetooth: Add new quirk for non-persistent diagnostic settings
If the diagnostic settings are not persistent over HCI Reset, then this quirk can be used to tell the Bluetoth core about it. This will ensure that the settings are programmed correctly when the controller is powered up. Signed-off-by: Marcel Holtmann <marcel@holtmann.org> Signed-off-by: Johan Hedberg <johan.hedberg@intel.com>
This commit is contained in:
parent
7841d06e43
commit
7e995b9ead
2 changed files with 28 additions and 0 deletions
|
@ -170,6 +170,15 @@ enum {
|
|||
* during the hdev->setup vendor callback.
|
||||
*/
|
||||
HCI_QUIRK_SIMULTANEOUS_DISCOVERY,
|
||||
|
||||
/* When this quirk is set, the enabling of diagnostic mode is
|
||||
* not persistent over HCI Reset. Every time the controller
|
||||
* is brought up it needs to be reprogrammed.
|
||||
*
|
||||
* This quirk can be set before hci_register_dev is called or
|
||||
* during the hdev->setup vendor callback.
|
||||
*/
|
||||
HCI_QUIRK_NON_PERSISTENT_DIAG,
|
||||
};
|
||||
|
||||
/* HCI device flags */
|
||||
|
|
|
@ -162,6 +162,16 @@ static ssize_t vendor_diag_write(struct file *file, const char __user *user_buf,
|
|||
if (strtobool(buf, &enable))
|
||||
return -EINVAL;
|
||||
|
||||
/* When the diagnostic flags are not persistent and the transport
|
||||
* is not active, then there is no need for the vendor callback.
|
||||
*
|
||||
* Instead just store the desired value. If needed the setting
|
||||
* will be programmed when the controller gets powered on.
|
||||
*/
|
||||
if (test_bit(HCI_QUIRK_NON_PERSISTENT_DIAG, &hdev->quirks) &&
|
||||
!test_bit(HCI_RUNNING, &hdev->flags))
|
||||
goto done;
|
||||
|
||||
hci_req_lock(hdev);
|
||||
err = hdev->set_diag(hdev, enable);
|
||||
hci_req_unlock(hdev);
|
||||
|
@ -169,6 +179,7 @@ static ssize_t vendor_diag_write(struct file *file, const char __user *user_buf,
|
|||
if (err < 0)
|
||||
return err;
|
||||
|
||||
done:
|
||||
if (enable)
|
||||
hci_dev_set_flag(hdev, HCI_VENDOR_DIAG);
|
||||
else
|
||||
|
@ -1494,6 +1505,14 @@ static int hci_dev_do_open(struct hci_dev *hdev)
|
|||
ret = __hci_init(hdev);
|
||||
}
|
||||
|
||||
/* If the HCI Reset command is clearing all diagnostic settings,
|
||||
* then they need to be reprogrammed after the init procedure
|
||||
* completed.
|
||||
*/
|
||||
if (test_bit(HCI_QUIRK_NON_PERSISTENT_DIAG, &hdev->quirks) &&
|
||||
hci_dev_test_flag(hdev, HCI_VENDOR_DIAG) && hdev->set_diag)
|
||||
ret = hdev->set_diag(hdev, true);
|
||||
|
||||
clear_bit(HCI_INIT, &hdev->flags);
|
||||
|
||||
if (!ret) {
|
||||
|
|
Loading…
Reference in a new issue