linux-hardened/Documentation/networking/slicecom.hun
John Anthony Kazos Jr be2a608bd0 documentation: convert the Documentation directory to UTF-8
Convert files within the Documentation directory to UTF-8.

Adrian Bunk:
small additional fixes

Signed-off-by: John Anthony Kazos Jr. <jakj@j-a-k-j.com>
Signed-off-by: Adrian Bunk <bunk@stusta.de>
2007-05-09 08:58:19 +02:00

371 lines
13 KiB
Text

SliceCOM adapter felhasznaloi dokumentacioja - 0.51 verziohoz
Bartók István <bartoki@itc.hu>
Utolso modositas: Wed Aug 29 17:26:58 CEST 2001
-----------------------------------------------------------------
Hasznalata:
Forditas:
Code maturity level options
[*] Prompt for development and/or incomplete code/drivers
Network device support
Wan interfaces
<M> MultiGate (COMX) synchronous
<M> Support for MUNICH based boards: SliceCOM, PCICOM (NEW)
<M> Support for HDLC and syncPPP...
A modulok betoltese:
modprobe comx
modprobe comx-proto-ppp # a Cisco-HDLC es a SyncPPP protokollt is
# ez a modul adja
modprobe comx-hw-munich # a modul betoltodeskor azonnal jelent a
# syslogba a detektalt kartyakrol
Konfiguralas:
# Ezen az interfeszen Cisco-HDLC vonali protokoll fog futni
# Az interfeszhez rendelt idoszeletek: 1,2 (128 kbit/sec-es vonal)
# (a G.703 keretben az elso adatot vivo idoszelet az 1-es)
#
mkdir /proc/comx/comx0.1/
echo slicecom >/proc/comx/comx0.1/boardtype
echo hdlc >/proc/comx/comx0.1/protocol
echo 1 2 >/proc/comx/comx0.1/timeslots
# Ezen az interfeszen SyncPPP vonali protokoll fog futni
# Az interfeszhez rendelt idoszelet: 3 (64 kbit/sec-es vonal)
#
mkdir /proc/comx/comx0.2/
echo slicecom >/proc/comx/comx0.2/boardtype
echo ppp >/proc/comx/comx0.2/protocol
echo 3 >/proc/comx/comx0.2/timeslots
...
ifconfig comx0.1 up
ifconfig comx0.2 up
-----------------------------------------------------------------
A COMX driverek default 20 csomagnyi transmit queue-t rendelnek a halozati
interfeszekhez. WAN halozatokban ennel hosszabbat is szokas hasznalni
(20 es 100 kozott), hogy a vonal kihasznaltsaga nagy terheles eseten jobb
legyen (bar ezzel megno a varhato kesleltetes a csomagok sorban allasa miatt):
# ifconfig comx0 txqueuelen 50
Ezt a beallitasi lehetoseget csak az ujabb disztribuciok ifconfig parancsa
tamogatja (amik mar a 2.2 kernelekhez keszultek, mint a RedHat 6.1 vagy a
Debian 2.2).
A 2.1-es Debian disztribuciohoz a http://www.debian.org/~rcw/2.2/netbase/
cimrol toltheto le ujabb netbase csomag, ami mar ilyet tamogato ifconfig
parancsot tartalmaz. Bovebben a 2.2 kernel hasznalatarol Debian 2.1 alatt:
http://www.debian.org/releases/stable/running-kernel-2.2
-----------------------------------------------------------------
A kartya LED-jeinek jelentese:
piros - eg, ha Remote Alarm-ot kuld a tuloldal
zold - eg, ha a vett jelben megtalalja a keretszinkront
Reszletesebben:
piros: zold: jelentes:
- - nincs keretszinkron (nincs jel, vagy rossz a jel)
- eg "minden rendben"
eg eg a vetel OK, de a tuloldal Remote Alarm-ot kuld
eg - ez nincs ertelmezve, egyelore funkcio nelkul
-----------------------------------------------------------------
Reszletesebb leiras a hardver beallitasi lehetosegeirol:
Az altalanos,- es a protokoll-retegek beallitasi lehetosegeirol a 'comx.txt'
fajlban leirtak SliceCOM kartyanal is ervenyesek, itt csak a hardver-specifikus
beallitasi lehetosegek vannak osszefoglalva:
Konfiguralasi interfesz a /proc/comx/ alatt:
Minden timeslot-csoportnak kulon comx* interfeszt kell letrehozni mkdir-rel:
comx0, comx1, .. stb. Itt beallithato, hogy az adott interfesz hanyadik kartya
melyik timeslotja(i)bol alljon ossze. A Cisco-fele serial3:1 elnevezesek
(serial3:1 = a 3. kartyaban az 1-es idoszelet-csoport) Linuxon aliasing-ot
jelentenenek, ezert mi nem tudunk ilyen elnevezest hasznalni.
Tobb kartya eseten a comx0.1, comx0.2, ... vagy slice0.1, slice0.2 nevek
hasznalhatoak.
Tobb SliceCOM kartya is lehet egy gepben, de sajat interrupt kell mindegyiknek,
nem tud meg megosztott interruptot kezelni.
Az egesz kartyat erinto beallitasok:
Az ioport es irq beallitas nincs: amit a PCI BIOS kioszt a rendszernek,
azt hasznalja a driver.
comx0/boardnum - hanyadik SliceCOM kartya a gepben (a 'termeszetes' PCI
sorrendben ertve: ahogyan a /proc/pci-ban vagy az 'lspci'
kimeneteben megjelenik, altalaban az alaplapi PCI meghajto
aramkorokhoz kozelebb eso kartyak a kisebb sorszamuak)
Default: 0 (0-tol kezdodik a szamolas)
Bar a kovetkezoket csak egy-egy interfeszen allitjuk at, megis az egesz kartya
mukodeset egyszerre allitjak. A megkotes hogy csak UP-ban levo interfeszen
hasznalhatoak, azert van, mert kulonben nem vart eredmenyekre vezetne egy ilyen
paranccsorozat:
echo 0 >boardnum
echo internal >clock_source
echo 1 >boardnum
- Ez a 0-s board clock_source-at allitana at.
Ezek a beallitasok megmaradnak az osszes interfesz torlesekor, de torlodnek
a driver modul ki/betoltesekor.
comx0/clock_source - A Tx orajelforrasa, a Cisco-val hasonlatosra keszult.
Hasznalata:
papaya:# echo line >/proc/comx/comx0/clock_source
papaya:# echo internal >/proc/comx/comx0/clock_source
line - A Tx orajelet a vett adatfolyambol dekodolja, igyekszik
igazodni hozza. Ha nem lat orajelet az inputon, akkor
atall a sajat orajelgeneratorara.
internal - A Tx orajelet a sajat orajelgeneratora szolgaltatja.
Default: line
Normal osszeallitas eseten a tavkozlesi szolgaltato eszkoze
(pl. HDSL modem) adja az orajelet, ezert ez a default.
comx0/framing - A CRC4 ki/be kapcsolasa
A CRC4: 16 PCM keretet (A PCM keret az, amibe a 32 darab 64
kilobites csatorna van bemultiplexalva. Nem osszetevesztendo a HDLC
kerettel.) 2x8 -as csoportokra osztanak, es azokhoz 4-4 bites CRC-t
szamolnak. Elsosorban a vonal minosegenek a monitorozasara szolgal.
papaya:~# echo crc4 >/proc/comx/comx0/framing
papaya:~# echo no-crc4 >/proc/comx/comx0/framing
Default a 'crc4', a MATAV vonalak altalaban igy futnak. De ha nem
egyforma is a beallitas a vonal ket vegen, attol a forgalom altalaban
at tud menni.
comx0/linecode - A vonali kodolas beallitasa
papaya:~# echo hdb3 >/proc/comx/comx0/linecode
papaya:~# echo ami >/proc/comx/comx0/linecode
Default a 'hdb3', a MATAV vonalak igy futnak.
(az AMI kodolas igen ritka E1-es vonalaknal). Ha ez a beallitas nem
egyezik a vonal ket vegen, akkor elofordulhat hogy a keretszinkron
osszejon, de CRC4-hibak es a vonalakon atvitt adatokban is hibak
keletkeznek (amit a HDLC/SyncPPP szinten CRC-hibaval jelez)
comx0/reg - a kartya aramkoreinek, a MUNICH (reg) es a FALC (lbireg)
comx0/lbireg regisztereinek kozvetlen elerese. Hasznalata:
echo >reg 0x04 0x0 - a 4-es regiszterbe 0-t ir
echo >reg 0x104 - printk()-val kiirja a 4-es regiszter
tartalmat a syslogba.
WARNING: ezek csak a fejleszteshez keszultek, sok galibat
lehet veluk okozni!
comx0/loopback - A kartya G.703 jelenek a visszahurkolasara is van lehetoseg:
papaya:# echo none >/proc/comx/comx0/loopback
papaya:# echo local >/proc/comx/comx0/loopback
papaya:# echo remote >/proc/comx/comx0/loopback
none - nincs visszahurkolas, normal mukodes
local - a kartya a sajat maga altal adott jelet kapja vissza
remote - a kartya a kivulrol vett jelet adja kifele
Default: none
-----------------------------------------------------------------
Az interfeszhez (Cisco terminologiaban 'channel-group') kapcsolodo beallitasok:
comx0/timeslots - mely timeslotok (idoszeletek) tartoznak az adott interfeszhez.
papaya:~# cat /proc/comx/comx0/timeslots
1 3 4 5 6
papaya:~#
Egy timeslot megkeresese (hanyas interfeszbe tartozik nalunk):
papaya:~# grep ' 4' /proc/comx/comx*/timeslots
/proc/comx/comx0/timeslots:1 3 4 5 6
papaya:~#
Beallitasa:
papaya:~# echo '1 5 2 6 7 8' >/proc/comx/comx0/timeslots
A timeslotok sorrendje nem szamit, '1 3 2' ugyanaz mint az '1 2 3'.
Beallitashoz az adott interfesznek DOWN-ban kell lennie
(ifconfig comx0 down), de ugyanannak a kartyanak a tobbi interfesze
uzemelhet kozben.
Beallitaskor leellenorzi, hogy az uj timeslotok nem utkoznek-e egy
masik interfesz timeslotjaival. Ha utkoznek, akkor nem allitja at.
Mindig 10-es szamrendszerben tortenik a timeslotok ertelmezese, nehogy
a 08, 09 alaku felirast rosszul ertelmezze.
-----------------------------------------------------------------
Az interfeszek es a kartya allapotanak lekerdezese:
- A ' '-szel kezdodo sorok az eredeti kimenetet, a //-rel kezdodo sorok a
magyarazatot jelzik.
papaya:~$ cat /proc/comx/comx1/status
Interface administrative status is UP, modem status is UP, protocol is UP
Modem status changes: 0, Transmitter status is IDLE, tbusy: 0
Interface load (input): 978376 / 947808 / 951024 bits/s (5s/5m/15m)
(output): 978376 / 947848 / 951024 bits/s (5s/5m/15m)
Debug flags: none
RX errors: len: 22, overrun: 1, crc: 0, aborts: 0
buffer overrun: 0, pbuffer overrun: 0
TX errors: underrun: 0
Line keepalive (value: 10) status UP [0]
// Itt kezdodik a hardver-specifikus resz:
Controller status:
No alarms
// Alarm: hibajelzes:
//
// No alarms - minden rendben
//
// LOS - Loss Of Signal - nem erzekel jelet a bemeneten.
// AIS - Alarm Indication Signal - csak egymas utani 1-esek jonnek
// a bemeneten, a tuloldal igy is jelezheti hogy meghibasodott vagy
// nincs inicializalva.
// AUXP - Auxiliary Pattern Indication - 01010101.. sorozat jon a bemeneten.
// LFA - Loss of Frame Alignment - nincs keretszinkron
// RRA - Receive Remote Alarm - a tuloldal el, de hibat jelez.
// LMFA - Loss of CRC4 Multiframe Alignment - nincs CRC4-multikeret-szinkron
// NMF - No Multiframe alignment Found after 400 msec - ilyen alarm a no-crc4
// es crc4 keretezesek eseten nincs, lasd lentebb
//
// Egyeb lehetseges hibajelzesek:
//
// Transmit Line Short - a kartya ugy erzi hogy az adasi kimenete rovidre
// van zarva, ezert kikapcsolta az adast. (nem feltetlenul veszi eszre
// a kulso rovidzarat)
// A veteli oldal csomagjainak lancolt listai, debug celokra:
Rx ring:
rafutott: 0
lastcheck: 50845731, jiffies: 51314281
base: 017b1858
rx_desc_ptr: 0
rx_desc_ptr: 017b1858
hw_curr_ptr: 017b1858
06040000 017b1868 017b1898 c016ff00
06040000 017b1878 017b1e9c c016ff00
46040000 017b1888 017b24a0 c016ff00
06040000 017b1858 017b2aa4 c016ff00
// A kartyat hasznalo tobbi interfesz: a 0-s channel-group a comx1 interfesz,
// es az 1,2,...,16 timeslotok tartoznak hozza:
Interfaces using this board: (channel-group, interface, timeslots)
0 comx1: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
1 comx2: 17
2 comx3: 18
3 comx4: 19
4 comx5: 20
5 comx6: 21
6 comx7: 22
7 comx8: 23
8 comx9: 24
9 comx10: 25
10 comx11: 26
11 comx12: 27
12 comx13: 28
13 comx14: 29
14 comx15: 30
15 comx16: 31
// Hany esemenyt kezelt le a driver egy-egy hardver-interrupt kiszolgalasanal:
Interrupt work histogram:
hist[ 0]: 0 hist[ 1]: 2 hist[ 2]: 18574 hist[ 3]: 79
hist[ 4]: 14 hist[ 5]: 1 hist[ 6]: 0 hist[ 7]: 1
hist[ 8]: 0 hist[ 9]: 7
// Hany kikuldendo csomag volt mar a Tx-ringben amikor ujabb lett irva bele:
Tx ring histogram:
hist[ 0]: 2329 hist[ 1]: 0 hist[ 2]: 0 hist[ 3]: 0
// Az E1-interfesz hiba-szamlaloi, az rfc2495-nek megfeleloen:
// (kb. a Cisco routerek "show controllers e1" formatumaban: http://www.cisco.com/univercd/cc/td/doc/product/software/ios11/rbook/rinterfc.htm#xtocid25669126)
Data in current interval (91 seconds elapsed):
9516 Line Code Violations, 65 Path Code Violations, 2 E-Bit Errors
0 Slip Secs, 2 Fr Loss Secs, 2 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 11 Unavail Secs
Data in Interval 1 (15 minutes):
0 Line Code Violations, 0 Path Code Violations, 0 E-Bit Errors
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in last 4 intervals (1 hour):
0 Line Code Violations, 0 Path Code Violations, 0 E-Bit Errors
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in last 96 intervals (24 hours):
0 Line Code Violations, 0 Path Code Violations, 0 E-Bit Errors
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
-----------------------------------------------------------------
Nehany kulonlegesebb beallitasi lehetoseg (idovel beepulhetnek majd a driverbe):
Ezekkel sok galibat lehet okozni, nagyon ovatosan kell oket hasznalni!
modified CRC-4, for improved interworking of CRC-4 and non-CRC-4
devices: (lasd page 107 es g706 Annex B)
lbireg[ 0x1b ] |= 0x08
lbireg[ 0x1c ] |= 0xc0
- ilyenkor ertelmezett az NMF - 'No Multiframe alignment Found after
400 msec' alarm.
FALC - a vonali meghajto IC
local loop - a sajat adasomat halljam vissza
remote loop - a kivulrol jovo adast adom vissza
Egy hibakeresesre hasznalhato dolog:
- 1-es timeslot local loop a FALC-ban: echo >lbireg 0x1d 0x21
- local loop kikapcsolasa: echo >lbireg 0x1d 0x00