linux-hardened/fs/freevxfs/vxfs_inode.h
Krzysztof Błaszkowski 1cce170179 freevxfs: update documentation and cresdits for HP-UX support
Signed-off-by: Krzysztof Błaszkowski <kb@sysmikro.com.pl>
[hch: cosmetic updates]
Signed-off-by: Christoph Hellwig <hch@lst.de>
2016-06-01 09:27:33 +02:00

194 lines
5.7 KiB
C

/*
* Copyright (c) 2000-2001 Christoph Hellwig.
* Copyright (c) 2016 Krzysztof Blaszkowski
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
* 1. Redistributions of source code must retain the above copyright
* notice, this list of conditions, and the following disclaimer,
* without modification.
* 2. The name of the author may not be used to endorse or promote products
* derived from this software without specific prior written permission.
*
* Alternatively, this software may be distributed under the terms of the
* GNU General Public License ("GPL").
*
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
* ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE FOR
* ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
* SUCH DAMAGE.
*
*/
#ifndef _VXFS_INODE_H_
#define _VXFS_INODE_H_
/*
* Veritas filesystem driver - inode structure.
*
* This file contains the definition of the disk and core
* inodes of the Veritas Filesystem.
*/
#define VXFS_ISIZE 0x100 /* Inode size */
#define VXFS_NDADDR 10 /* Number of direct addrs in inode */
#define VXFS_NIADDR 2 /* Number of indirect addrs in inode */
#define VXFS_NIMMED 96 /* Size of immediate data in inode */
#define VXFS_NTYPED 6 /* Num of typed extents */
#define VXFS_TYPED_OFFSETMASK (0x00FFFFFFFFFFFFFFULL)
#define VXFS_TYPED_TYPEMASK (0xFF00000000000000ULL)
#define VXFS_TYPED_TYPESHIFT 56
#define VXFS_TYPED_PER_BLOCK(sbp) \
((sbp)->s_blocksize / sizeof(struct vxfs_typed))
/*
* Possible extent descriptor types for %VXFS_ORG_TYPED extents.
*/
enum {
VXFS_TYPED_INDIRECT = 1,
VXFS_TYPED_DATA = 2,
VXFS_TYPED_INDIRECT_DEV4 = 3,
VXFS_TYPED_DATA_DEV4 = 4,
};
/*
* Data stored immediately in the inode.
*/
struct vxfs_immed {
__u8 vi_immed[VXFS_NIMMED];
};
struct vxfs_ext4 {
__fs32 ve4_spare; /* ?? */
__fs32 ve4_indsize; /* Indirect extent size */
__fs32 ve4_indir[VXFS_NIADDR]; /* Indirect extents */
struct direct { /* Direct extents */
__fs32 extent; /* Extent number */
__fs32 size; /* Size of extent */
} ve4_direct[VXFS_NDADDR];
};
struct vxfs_typed {
__fs64 vt_hdr; /* Header, 0xTTOOOOOOOOOOOOOO; T=type,O=offs */
__fs32 vt_block; /* Extent block */
__fs32 vt_size; /* Size in blocks */
};
struct vxfs_typed_dev4 {
__fs64 vd4_hdr; /* Header, 0xTTOOOOOOOOOOOOOO; T=type,O=offs */
__fs64 vd4_block; /* Extent block */
__fs64 vd4_size; /* Size in blocks */
__fs32 vd4_dev; /* Device ID */
__u8 __pad1;
};
/*
* The inode as contained on the physical device.
*/
struct vxfs_dinode {
__fs32 vdi_mode;
__fs32 vdi_nlink; /* Link count */
__fs32 vdi_uid; /* UID */
__fs32 vdi_gid; /* GID */
__fs64 vdi_size; /* Inode size in bytes */
__fs32 vdi_atime; /* Last time accessed - sec */
__fs32 vdi_autime; /* Last time accessed - usec */
__fs32 vdi_mtime; /* Last modify time - sec */
__fs32 vdi_mutime; /* Last modify time - usec */
__fs32 vdi_ctime; /* Create time - sec */
__fs32 vdi_cutime; /* Create time - usec */
__u8 vdi_aflags; /* Allocation flags */
__u8 vdi_orgtype; /* Organisation type */
__fs16 vdi_eopflags;
__fs32 vdi_eopdata;
union {
__fs32 rdev;
__fs32 dotdot;
struct {
__u32 reserved;
__fs32 fixextsize;
} i_regular;
struct {
__fs32 matchino;
__fs32 fsetindex;
} i_vxspec;
__u64 align;
} vdi_ftarea;
__fs32 vdi_blocks; /* How much blocks does inode occupy */
__fs32 vdi_gen; /* Inode generation */
__fs64 vdi_version; /* Version */
union {
struct vxfs_immed immed;
struct vxfs_ext4 ext4;
struct vxfs_typed typed[VXFS_NTYPED];
} vdi_org;
__fs32 vdi_iattrino;
};
#define vdi_rdev vdi_ftarea.rdev
#define vdi_dotdot vdi_ftarea.dotdot
#define vdi_fixextsize vdi_ftarea.regular.fixextsize
#define vdi_matchino vdi_ftarea.vxspec.matchino
#define vdi_fsetindex vdi_ftarea.vxspec.fsetindex
#define vdi_immed vdi_org.immed
#define vdi_ext4 vdi_org.ext4
#define vdi_typed vdi_org.typed
/*
* The inode as represented in the main memory.
*/
struct vxfs_inode_info {
struct inode vfs_inode;
__u32 vii_mode;
__u32 vii_nlink; /* Link count */
__u32 vii_uid; /* UID */
__u32 vii_gid; /* GID */
__u64 vii_size; /* Inode size in bytes */
__u32 vii_atime; /* Last time accessed - sec */
__u32 vii_autime; /* Last time accessed - usec */
__u32 vii_mtime; /* Last modify time - sec */
__u32 vii_mutime; /* Last modify time - usec */
__u32 vii_ctime; /* Create time - sec */
__u32 vii_cutime; /* Create time - usec */
__u8 vii_orgtype; /* Organisation type */
union {
__u32 rdev;
__u32 dotdot;
} vii_ftarea;
__u32 vii_blocks; /* How much blocks does inode occupy */
__u32 vii_gen; /* Inode generation */
union {
struct vxfs_immed immed;
struct vxfs_ext4 ext4;
struct vxfs_typed typed[VXFS_NTYPED];
} vii_org;
};
#define vii_rdev vii_ftarea.rdev
#define vii_dotdot vii_ftarea.dotdot
#define vii_immed vii_org.immed
#define vii_ext4 vii_org.ext4
#define vii_typed vii_org.typed
static inline struct vxfs_inode_info *VXFS_INO(struct inode *inode)
{
return container_of(inode, struct vxfs_inode_info, vfs_inode);
}
#endif /* _VXFS_INODE_H_ */