bouyer
93b483ae63 Update to 3.12.4.
Summary of changes since 3.8.6:
* Support for USB UPSe (not enabled in pkgsrc)
* new networking driver (net) that uses the NIS interface rather than the
  older master/slave networking
* The apctest program has been enhanced to do EEPROM programming in a much
  more interactive way than the prior versions.
* Added a ONBATTERYDELAY config, time to switch to onbattery state after
  a power failure. New event "offbattery", which is the same as mainsback but
  only sent if we got to state onbattery
* new snmp driver, with trap support.
* Battery disconnect and reconnect events
2006-11-15 21:46:24 +00:00
bouyer
9d1c4a507a Update to 3.8.5. Summary of changes since 3.6.2:
. New network interface to publish to clients the UPS status
. New master/server network code that is more fault tolerant
. Internationalization
. Use GNU getopt
. Logging on syslog
. Events logged in a file like APC's PowerChute
. Sync code removed: now only async processes are used
. Updated documentation (HTTP version)
. Bug fixes and enhancements: too many to tell them all
. no more powersc script, is has been remplaced with apccontrol
. In master/slave configurations, all masters and slaves
  must be updated at the same time. Version 3.8.0 is not
  compatible with versions prior to 3.8.0-pre4.
. Support for the Back-UPS Office series of UPSes
. Fixed dumb UPSes working with the Custom Simple cable.
. Correction of a buffer overflow on certain newer UPSes.
. More fault tolerant on startup in master/slave configuration.
. Additional STATUS variables (number of times on battery,
  amount of time on batteries, time/date of last transfer to
  batteries, apcupsd start time/date).
. apctest program for testing serial ports.
. Automatic notification of certain events by email.
. Detects Self Test and reports it as such rather than a
  Power Failure.
. For SmartUPSes, apcupsd does a much better job of adapting
  to the actual features of the UPS and is more efficient.
. Add Battery Runtime Calibration to apctest
. UPSNAME now sets upsname if given. Otherwise, apcupsd attempts to get name
  from UPS, if not found, uses hostname, finally "default".
. Added Ambient Temperature and Humidity to multimon (Carl Erhorn)

A number of the configuration statements have changed since versions 3.6.2.
You should either take the new apcupsd.conf file and modify it, or update your
existing file. In general, we recommend starting with the new file.

If you have used a prior version of apcupsd, the CONTROL script file
(/sbin/powersc) has now been replaced by $SYSCONFDIR/apcupsd/apccontrol.
Consequently, the CONTROL configuration statement is obsolete. The following
configuration statements have been replaced by scripts called from
SYSCONDFIR/apcupsd/apccontrol, and thus are obsolete:
BATTCMD, LIMITCMN, LOADCMD, PWRCMD, REBOOTCMD, REMOTECMD, RETCMD, and TIMECMD.
If you use the master/slave networking code, please be aware that the
2002-12-01 22:32:25 +00:00
jlam
2ced1f27a2 Update apcupsd to 3.6.2. Package provided by Greg Woods <woods@weird.com>
in pkg/10552.  Changes from version 3.5.8:

	Network is fully functional under non-threaded compile.
	Possible fix for "pipe_master_status" calls on slaves.
	Added 940-1524C smart signal cable support.

	Added internationalization support. There is _only_ the support but
	no current code is written for the intl package. It can be compiled
	in, but intl strings have still to be translated (to be done in the
	future).

	Added new configuration options to reduce init time of daemon.
	powersc CONFIG
	powersc NAME
	powersc BATTERY

	Fixes a FIFO error
2000-08-05 07:31:15 +00:00
bouyer
9de579284d apcupsd, a daemon to manage and monitor APC UPSes. 2000-01-21 19:15:59 +00:00