. New network interface to publish to clients the UPS status . New master/server network code that is more fault tolerant . Internationalization . Use GNU getopt . Logging on syslog . Events logged in a file like APC's PowerChute . Sync code removed: now only async processes are used . Updated documentation (HTTP version) . Bug fixes and enhancements: too many to tell them all . no more powersc script, is has been remplaced with apccontrol . In master/slave configurations, all masters and slaves must be updated at the same time. Version 3.8.0 is not compatible with versions prior to 3.8.0-pre4. . Support for the Back-UPS Office series of UPSes . Fixed dumb UPSes working with the Custom Simple cable. . Correction of a buffer overflow on certain newer UPSes. . More fault tolerant on startup in master/slave configuration. . Additional STATUS variables (number of times on battery, amount of time on batteries, time/date of last transfer to batteries, apcupsd start time/date). . apctest program for testing serial ports. . Automatic notification of certain events by email. . Detects Self Test and reports it as such rather than a Power Failure. . For SmartUPSes, apcupsd does a much better job of adapting to the actual features of the UPS and is more efficient. . Add Battery Runtime Calibration to apctest . UPSNAME now sets upsname if given. Otherwise, apcupsd attempts to get name from UPS, if not found, uses hostname, finally "default". . Added Ambient Temperature and Humidity to multimon (Carl Erhorn) A number of the configuration statements have changed since versions 3.6.2. You should either take the new apcupsd.conf file and modify it, or update your existing file. In general, we recommend starting with the new file. If you have used a prior version of apcupsd, the CONTROL script file (/sbin/powersc) has now been replaced by $SYSCONFDIR/apcupsd/apccontrol. Consequently, the CONTROL configuration statement is obsolete. The following configuration statements have been replaced by scripts called from SYSCONDFIR/apcupsd/apccontrol, and thus are obsolete: BATTCMD, LIMITCMN, LOADCMD, PWRCMD, REBOOTCMD, REMOTECMD, RETCMD, and TIMECMD. If you use the master/slave networking code, please be aware that the
11 lines
473 B
Text
11 lines
473 B
Text
===========================================================================
|
|
$NetBSD: MESSAGE,v 1.2 2002/12/01 22:32:25 bouyer Exp $
|
|
|
|
NOTE: With most APC cables you must put a "local" flag in /etc/ttys for
|
|
the port you connect your UPS to, and run "ttyflags -a" to turn it
|
|
on the first time.
|
|
|
|
for complete documentation, see the html docs in
|
|
file://${PREFIX}/share/doc/html/apcupsd
|
|
|
|
===========================================================================
|